SN-N103E Gas Transmission Rate Tester

SN-N103E Gas Transmission Rate Tester

Gas kis tus nqi Tester
Lub siab precision gas permeability tester yog lub tshuab sophisticated uas xyuas seb cov pa roj zoo li oxygen, carbon dioxide, thiab nitrogen tuaj yeem dhau los ntawm cov khoom ntim. Nws pab txiav txim siab seb lub ntim khoom puas ua rau muaj kev cuam tshuam rau cov roj no, uas yog qhov tseem ceeb rau kev khaws cov khoom tshiab thiab nyab xeeb.
Xa kev nug
Khoom Taw qhia

Cov qauv

ISO 15105-1, ISO 2556, GB / T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003

Daim ntawv thov teb

Ntim|Khoom noj|Tshuaj|Cov ntaub ntawv tshiab|Kev lag luam tshuaj|Kev luam ntawv

Npaj siv

Siv los txiav txim siab cov pa xa hluav taws xob (GTR) ntawm O2, CO2, N2 thiab lwm cov pa roj rau ntau cov yeeb yaj kiab thiab cov khoom ntim.

Haum rau kev ntsuas roj permeability ntawm cov yeeb yaj kiab, cov ntawv, ntawv, pob ntawv, thiab cov ntaub ntawv muaj feem xyuam hauv kev lag luam xws li zaub mov, tshuaj, khoom siv kho mob, tshuaj txhua hnub, thiab photovoltaic electronics. Nws muab qhov dav -ntau yam thiab siab- kuaj pom kev ua haujlwm zoo rau cov khoom siv nrog siab, nruab nrab, thiab qis roj barrier zog.

Txoj Cai Kev Ua Haujlwm

Raws li lub hauv paus ntsiab lus ntawm txoj kev sib txawv siab. Cov qauv ua ntej -conditioned specimen yog muab tso rau nruab nrab ntawm qhov siab thiab qis- cov chav ntsuas siab thiab clamped. Tom qab ntawd tag nrho cov kev xeem yuav khiav tawm. Thaum kawg, cov roj ntsuas tau ntim rau hauv lub siab -siab chamber kom muaj qhov sib txawv ntawm qhov sib txawv ntawm qhov ntsuas. Tsav los ntawm lub siab gradient, cov pa roj permeates los ntawm lub siab - siab chamber los ntawm cov zaj duab xis mus rau hauv lub qis - siab chamber. Los ntawm kev saib xyuas qhov kev hloov siab nyob rau hauv qhov qis -siab chamber, qhov barrier parameters ntawm tus qauv tuaj yeem xam tau.

Khoom nta

  1. Cim chamber thiab pneumatic Circuit Court tsim; qhov ntim ntawm qhov qis -siab chamber yog adjustable los muab ntau yam kev ntsuam xyuas.
  2. Nruab nrog imported sensors, kom ntseeg tau siab precision thiab zoo heev stability.
  3. Siv cov txheej txheem PID kub tswj kev ua haujlwm siab rau siab -txheej txheem thermal tswj.
  4. Tiag - lub sij hawm tso saib ntawm tus nqi kis tau tus mob, siab, thiab kub nkhaus rau kev nyob taug qab ntawm lub ntsuas ntsuas kev ua haujlwm.
  5. Yooj yim software interface thiab ua haujlwm yooj yim nrog kev xaiv tsis siv neeg lossis phau ntawv xeem hom; cov ntawv xeem tau txais kev cawmdim thiab tuaj yeem luam tawm txhua lub sijhawm.
  6. Loj -scale txij nkawm- pub dawb tsim nrog kev ua tau zoo tshaj plaws rau xyoo- ua haujlwm tas mus li; nruab nrog tshaj - kev tiv thaiv kev ruaj ntseg.
  7. Lub mainframe yog nruab nrog lub touchscreen HMI (Tib neeg-Machine Interface) los tso saib tag nrho cov kev ntsuas ib txhij.

Technical Parameters

Yam khoom

Parameter

Kuaj Ntau

0.02-50000cm³ / (m².24h.0.1MPa)

Kev ntsuas qhov tseeb

Tsis pub dhau ± 2% ntawm kev nyeem ntawv

Qhov kub thiab txias

5℃-55 degree

Temp. Tswj qhov tseeb

± 0.5 degree

Standard Test Temp.

23 degree

Vacuum Degree

27 Pa

Chaw kuaj

50.26 cm² (Yeem rau lwm tus)

Qauv Thickness

Tsawg dua los yog sib npaug li 3 hli

Gas Inlet Chaw nres nkoj

Φ8 hli PU Tubing

Nqus Chaw nres nkoj

1/8 nti

Test Gas Siab

0.1MPa

Gas Source Pressure

Ntau dua lossis sib npaug li 0.4MPa

Number of Specimens

3

Fais fab mov

AC 220V / 50Hz

Khoom Configuration

Standard Configuration

Mainframe, Fais Fab Cable, Kev Sib Txuas Lus Cable, Stainless Hlau Tube, Pneumatic Tubing, Qauv Cutter, Cov Ntawv Lim Zoo, Nqus Roj, Txhim Kho Accessories

Cov neeg siv - muab cov khoom

Compressed Cua (Hloov siab dua los yog sib npaug rau 0.4 MPa, Φ8 mm PU tubing), Test Gas (O2, 99.999% Purity), Nqus Pump (Flow rate 4L/s, Vacuum℃6 * 10-2), PC

Cim npe nrov: SN-N103E Gas Transmission Rate Tester, Tuam Tshoj SN-N103E Gas Transmission Rate Tester manufacturers, lwm tus neeg, Hoobkas

Xa kev nug

whatsapp

Xov tooj

Tug

Kev nug