Cov khoom siv chromatography

Cov khoom siv chromatography

Muaj-Qib Chromatography Cov Khoom Siv Nrog Txhim Kho Kev Ruaj Ntseg & Ceev
1.Siv los xyuas cov kuab tshuaj residue ntawm ntim cov ntawv luam tawm.
2.Siv los xyuas qhov purity thiab cov ntsiab lus ntawm cov kuab tshuaj.
Gas Chromatographs (GC) yog cov cuab yeej tshuaj ntsuam xyuas ntau yam siv dav hauv kev lag luam rau kev sib cais thiab tshuaj xyuas cov tebchaw tsis zoo.
Xa kev nug
Khoom Taw qhia

Khoom Parameter (Specification)

 

Muaj-Qib Chromatography Cov Khoom Siv Nrog Txhim Kho Kev Ruaj Ntseg & Ceev

 

Yam khoom

Parameter

FID Detection Limit

Tsawg dua lossis sib npaug li 5e-11 g / s

FID Stability

Lub suab nrov: Tsawg dua lossis sib npaug ntawm 1e-12 A; Baseline Drift: Tsawg dua lossis sib npaug rau 1e-11 A / 30 min

Qualitative Repeatability

Tsawg dua lossis sib npaug li 1%

Quantitative Repeatability

Tsawg dua lossis sib npaug li 3%

Qhov kub thiab txias

Chav ntsuas kub +5 txog 300 degree

Kub qhov tseeb

± 0.1 degree

Programmed Temperature Ramp Rate

0.1-25℃/ min

Kem Qhov Cub Txias Rate

Tsawg dua lossis sib npaug li 9 min (los ntawm 300℃txog 70 degree)

Gas Txoj Kev Tswj

Mechanical Valve Control

 

Khoom Feature Thiab Daim Ntawv Thov

 

Khoom feature

1.Ua- nyob rau hauv lub suab qis, siab daws teeb meem 24-ntsis AD Circuit Court, thiab muaj kev ua haujlwm ntawm qhov chaw khaws cia thiab kev txiav tawm hauv paus.
2.Lub chromatographic microcomputer system uas muaj kev ywj pheej ntawm kev txawj ntse muaj cai muaj cov txheej txheem raws tu qauv MODBUS/TCP, uas tuaj yeem txuas rau DCS system (yeem).
3.FID siv logarithmic amplifier; Tag nrho EPC hluav taws xob khiav tswj qhov system.
4.Kub tswj cheeb tsam nroog: 8 txoj kev; Kev tswj qhov kub thiab txias: chav kub siab tshaj 4 ° ~ 450 ° C, nce ntxiv: 0.5C; Qhov tseeb: ± 0.1C
5.Injector hom: filling kab txhaj tshuaj, capillary txhaj, rau - txoj kev valve gas txhaj, tsis siv neeg txhaj tshuaj (yeem).
6.High-Sensitivity Detectors – Nruab nrog cov cuab yeej xws li FID (Nplaim Ionization Detector), ECD (Electron Capture Detector), TCD (Tshav Kub Kub Detector), lossis FPD thiab NPD rau kev tshuaj xyuas meej ntawm cov kab sib txuas.

Gas Chromatography Daim Ntawv Thov

1.Hydrocarbon Analysis – Characterization of crude oils, refined fuels, and natural gas Cheebtsam (xws li, alkanes, aromatics).
2.Fuel Quality Control – Kev ntsuas ntawm octane/cetane tooj thiab leej faj cov ntsiab lus.
3.Polymers & Plastics - Kev tshuaj xyuas ntawm monomers, additives, thiab 4.Chemical Synthesis - Saib xyuas cov tshuaj tiv thaiv nruab nrab thiab cov khoom purity.

 

Paub meej ntau lawm

 

product-800-800
product-800-800

 

Khoom tsim nyog

 

GB 31604.60-2024, GB/T 10004-2008, GB/T 30431-2020, GB/T 40266-2021, YBB00132002-2015, YBB00312004-2015

 

Xa, Shipping Thiab Pab

 

Ua ntej-Kev Pabcuam Muag

Xaus-rau- xaus ua ntej- kev muag khoom: los ntawm kev xav tau kev tshuaj ntsuam xyuas kom kaw cov neeg siv khoom sib koom ua ke los ntawm kev txheeb xyuas cov kev xav tau, kev tsim cov lus pom zoo nrog tus nqi- cov txiaj ntsig kev puas tsuaj, thiab kev txiav txim siab ua tiav kom ntseeg tau tias muaj kev sib raug zoo nrog cov phiaj xwm tshwj xeeb.

Hauv -Kev Muag Khoom

Peb tswj txhua yam ntawm cov txheej txheem muag khoom, suav nrog kev qhia meej txog tus nqi, lub sijhawm xa khoom, thiab nqe lus them nqi, nrog rau kev ua tiav cov ntawv cog lus. Txhawm rau kom ntseeg tau tias siv tau zoo, peb muab kev qhia ua haujlwm thiab kev saib xyuas. Txhua lub cuab yeej ua tiav kev sim nruj thiab kev debugging ua ntej ua zaub mov xa tuaj kom ntseeg tau tias nws ua tau raws li txhua daim ntawv cog lus.

Tom qab -Kev Muag Khoom

Peb tau cog lus rau koj lub sijhawm ntev - kev txaus siab. Ntxiv nrog rau 1-xyoo lav, peb muab kev txhawb nqa kev pab cuam lub neej ntev, kev saib xyuas tsis tu ncua, thiab kev daws teeb meem sai rau txhua qhov teeb meem koj yuav ntsib. Peb lub hom phiaj yog los xyuas kom meej tias koj cov cuab yeej ua tau zoo thoob plaws hauv nws lub neej.

 

FAQ

 

Q: Txog GC Calibration, Kuv yuav ntsuas kuv GC li cas rau kev txheeb xyuas ntau?

A: Siv cov qauv siv ntawv pov thawj los tsim kom muaj qhov nkhaus calibration.
Siv tau nrog kev tswj xyuas zoo (QC) cov qauv los xyuas kom meej thiab meej.

 

Cim npe nrov: Tuam Tshoj chromatography khoom manufacturers, lwm tus neeg, Hoobkas

Xa kev nug

whatsapp

Xov tooj

Tug

Kev nug