GC-02E Gas Chromatograph
Cov qauv
GB 31604.60-2024, GB/T 10004-2008, GB/T 30431-2020, GB/T 40266-2021, YBB00132002-2015, YBB00312004-2015
Daim ntawv thov teb
Ntim|Khoom noj|Tshuaj|Cov ntaub ntawv tshiab|Kev lag luam tshuaj|Kev luam ntawv
Npaj siv
- Solvent Residue Analysis: Tshwj xeeb tsim los kuaj xyuas cov kuab tshuaj residues hauv ntim thiab cov ntaub ntawv luam tawm.
- Purity & Content Testing: Siv los ntsuas qhov purity thiab ntau cov ntsiab lus ntawm ntau yam kuab tshuaj.
- Cov khoom uas kuaj tau: Benzene, Cyclohexanone, Xylene, Ethanol, Ethylbenzene, Isopropanol, Propanol, Butanol, Ethyl Acetate, Isopropyl Acetate, n-Butanol, Toluene, n-Butyl Acetate, IB-Metlanone, thiab lwm yam.
Txoj Cai Kev Ua Haujlwm
Gas Chromatograph (GC) siv cov roj inert raws li lub sijhawm txawb thiab siv cov cuab yeej sib cais. Raws li qhov sib tov tshuaj ntsuam xyuas nkag mus rau hauv chromatographic kem, ib tus neeg cov khoom txav ntawm tus nqi sib txawv vim lawv qhov sib txawv ntawm cov coefficients sib txawv hauv kem. Thaum sib cais, cov khoom sib txuas nkag mus rau hauv lub ntsuas, qhov chaw uas lawv hloov mus rau hauv hluav taws xob teeb liab thiab xa mus rau ib lub chaw ua haujlwm cov ntaub ntawv rau kev soj ntsuam zoo thiab ntau yam.
Khoom nta
- Kev Sib Tham Ntse: Ua kom muaj 7- nti xim touchscreen nrog rau tom ntej - tiam ntse OS, muab lub xov tooj zoo li kev nkag siab zoo thiab cov ntsiab lus meej.
- Expandable Detectors: tuaj yeem nruab nrog ntau lub tshuab ntes ib txhij. Ua tau zoo nrog chromatographic workstations rau intuitive tshwm sim pom.
- Siab- Ua kom txias txias: Loj- lub peev xwm kem qhov cub muaj qhov tsis siv neeg rov qab- qhov rooj mechanism kom txias ceev.
- Ntau hom Txhaj Tshuaj: Configurable rau Ntim / Capillary kem injectors, Headspace autosamplers, Thermal Desorption (TD), Pyrolysis (Py), thiab lwm yam.
- Kev nyab xeeb & Kev kuaj mob: suav nrog tus kheej- muaj peev xwm kuaj mob thiab tshaj- tiv thaiv qhov kub thiab txias, uas cia li nres cua sov thiab ua rau lub tswb ceeb toom yog tias muaj ntau dua.
- Ultra-Kev Ua Haujlwm ntsiag to: muaj lub suab nrov tshaj plaws uas tshem tawm cov kiv cua nrov thaum ua haujlwm.
- Saj zawg zog Architecture: Ntau qhov chaw nres nkoj injector tsim thiab lub qhov cub dav ua kom yooj yim rau kev txheeb xyuas cov haujlwm uas siv ntau kab, nthuav dav cov qauv ntawm cov qauv kuaj.
- Precision Control: Microcomputer- tswj nrog qhov kub thiab txias qhov tseeb ntawm .
- Dual Overheat Protection: nta kho vajtse Circuit Court thiab software program redundancy kom muaj kev nyab xeeb siab tshaj plaws.
Technical Parameters
|
Yam khoom |
Parameter |
|
Carrier Gas |
Nitrogen (N₂), Purity Ntau dua lossis sib npaug li 99.99% |
|
Roj Roj |
Hydrogen (H₂), Purity Ntau dua lossis sib npaug li 99.99% |
|
Makeup Gas |
Cua, Purified roj- huab cua dawb |
|
FID Detection Limit |
Mt Tsawg dua lossis sib npaug rau 1 × 10ˉ¹¹g/s(nC16) |
|
Kev ruaj ntseg (FID) |
Baseline Drift Tsawg dua lossis sib npaug rau 0.2MV / 0.5h, Suab nrov tsawg dua lossis sib npaug rau 0.2MV |
|
TCD Sensitivity |
Sensitivity S Ntau dua lossis sib npaug rau 2500mV·ml / mg (Benzene) |
|
Kev ruaj ntseg (TCD) |
Baseline Drift Tsawg dua lossis sib npaug rau 25uV / 0.5h, Suab nrov tsawg dua lossis sib npaug rau 10uV |
|
Txias tus nqi |
Tsawg dua lossis sib npaug li 9 min (300℃txog 70 degree) |
|
RSD |
Tsawg dua lossis sib npaug li 1% |
|
Temp. Tswj ntau yam |
Ambient 十5℃~ 300 degree |
|
Temp. Program Rate |
0.1 ~ 25℃/ min |
|
Fais fab mov |
AC 220V / 50Hz |
|
Qhov ntev |
530mm * 500mm * 440mm |
Standard Configuration
PC, Analytical Reagents, Gas Source (N₂, H₂, Air, thiab Pressure Reduction Valves).
Cov neeg siv - muab cov khoom
PC, Analytical Reagents, Gas Source (N₂, H₂, Cua, thiab 0.35 ~ 0.4MPa Siab Txo Valves).
Cim npe nrov: GC-02E Gas Chromatograph, Tuam Tshoj GC-02E Gas Chromatograph manufacturers, lwm tus neeg, Hoobkas
Tom ntej
GC-06E Gas ChromatographKoj Tseem Yuav Zoo Li
Xa kev nug