SD-2J Tsis Siv Neeg Solvent Moisture Tester
Cov qauv
GB/T 7600-1987, GB 6283-1982, SH/T 0246, GB/T 11133-1989, GB/T 1600, GB/T 11146, GB/T 12717, GB/T 5074
Daim ntawv thov teb
Ntim|Khoom noj|Tshuaj|Cov ntaub ntawv tshiab|Kev lag luam tshuaj|Kev luam ntawv
Npaj siv
Kev sib koom ua ke tsim kho mechatronic siab heev nrog tus neeg siv -centric interface, qhov ntsuas no muaj peev xwm txiav txim siab dej siv lead ua, dej adsorbed, thiab dej dawb hauv cov kua, khoom, thiab gaseous. Nws yog dav siv hauv kev lag luam xws li roj av, tshuaj, tshuaj, tshuaj, tshuaj txhua hnub, zaub mov, kev ua liaj ua teb, thiab ntau yam kev sim hauv ib puag ncig.
Txoj Cai Kev Ua Haujlwm
Lub ntsuas dej noo siv Karl Fischer Volumetric Method rau kev txiav txim siab noo noo, muab kev ntsuas siab ua ke nrog rau kev ua kom yooj yim thiab cov neeg siv- ua haujlwm zoo.
Khoom nta
- Loj Xim LCD: Nta lub siab -txhais xim npo nrog cov ntawv qhia zaub mov suav ntau yam - tsav interface.
- Kev Ua Haujlwm Zoo: Muab qhov tseeb - lub sijhawm dynamic prompts thiab lub Windows -style ua haujlwm logic rau tshwj xeeb yooj yim ntawm kev siv.
- Cov ntaub ntawv nthuav dav: Ib txhij qhia cov dej noo, feem pua, PPM, thiab reagent noj. Xws li dynamic xim titration nkhaus thiab tsis siv neeg nco rau kev ntsuas tau.
- Drift Compensation: Tsis siv neeg txiav tawm cov dej noo noo thiab taug qab qhov hloov pauv ntawm cov dej noo nyob ib puag ncig hauv lub sijhawm tiag tiag - kom ntseeg tau qhov tseeb tshaj plaws analytical.
- PWM Stirring Control: Siv Pulse Width Modulation (PWM) rau stepless stirring ceev hloov, xaiv tau ncaj qha los ntawm cov ntawv qhia zaub mov.
- Fully Sealed System: Cov qauv tsim airtight tso cai rau kev hloov pauv cov kuab tshuaj tsis siv neeg thiab cov pov tseg pov tseg, tiv thaiv kom tsis txhob tawm los yog dhau ntawm cov tshuaj lom neeg.
- Tiag - Sijhawm Saib Xyuas: Instantaneous display of instrument status, metering pump volume, current time, three-way valve position, and drift rate.
Technical Parameters
|
Yam khoom |
Parameter |
|
Kev ntsuas ntau |
0.001%-100% |
|
Kev daws teeb meem |
0.01ml ib |
|
Zaub hom |
Ntxiv - Xim LCD loj |
|
Titration Flow Rate |
Tsis siv neeg tswj |
|
Xaus -point Delay |
10-300s (Adjustable) |
|
Indication yuam kev |
Tsawg dua lossis sib npaug li 2% |
|
Fais fab mov |
AC 220V / 50Hz |
|
Standard Configuration |
Mainframe, Ib txheej ntawm Installation Accessories, Fais Fab Cable. |
|
Xaiv cov khoom siv |
Lub tshuab luam ntawv |
|
Cov neeg siv - muab cov khoom |
Karl Fischer Reagent, Anhydrous Methanol. |
Cim npe nrov: Tuam Tshoj SD-2J Tsis Siv Neeg Solvent Moisture Tester manufacturers, lwm tus neeg, Hoobkas